Limited Warranty - Standard 5-year limited warranty on parts and 5-year limited warranty on compressor parts. Each valve has a service port for ease of checking operating refrigerant pressures. Valves are externally located so refrigerant tube connections can be made quickly and easily.
External Service Valves - Both service valves are brass, front seating type. Coil can be cleaned with a common garden hose.
The vertical air discharge carries the sound and air up and away from adjacent patio areas and foliage. The large, wraparound coil uses copper tube and enhanced aluminum fin and is designed for optimum heat transfer during heating and cooling. Unit Design - All units are equipped with totally enclosed fan motors for greater reliability under adverse weatherĬonditions. All screws on cabinet exterior are coated for a long-lasting, rust-resistant, quality appearance. A modified polyester powder coating is then applied and baked on, providing each unit with a hard, smooth finish that will last for many years. WeatherArmor™ Cabinet - Casing steel is protected with a galvanized coating and treated with a layer of zinc phosphate. The defrost control is a time and temperature initiation/termination control which includes 3 field-selectable time periods of 30, 50, and 90 minutes. Defrost Control Board - Incorporates a defrost relay, defrost timer, and low-voltage terminations. Pulsation generated by compressor discharge gas. Discharge Muffler - Minimizes low frequency sound and pressure 3-Phase (Scroll Compressor Units) Monitor Board-Control board that monitors the electrical phase and prevents compressor operation if wired incorrectly.
Carrier fk4dnf002 seer free#
(See heating and cooling performance tables.) Reliable Standard Components - Includes a suction-tube accumulator that reduces the amount of liquid refrigerant that reaches the compressor a lowpressure switch to stop the compressor if refrigerant charge is lost a crankcase heater on all 3-phase units (except 030 size) to keep compressor oil warm and free of refrigerant for maximum lubricity an internal compressor relief valve for high-pressure protection. (12.8☌) in the cooling mode (unless equipped for low-ambient operation). Continuous compressor operation is approved down to –30☏ (–34.4☌) in the heating mode, and down to 55☏ For improved serviceability, all models are equipped with a compressor terminal plug. Each compressor is hermetically sealed against contamination to assure long life and dependable performance compressors are also externally mounted on rubber isolators for quiet operation. Compressor - Designed specifically for heat pump duty, with energy efficiency during heating and cooling operation. Size Range - The 38YCC is available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. The 38YCC 030 through 060 models are offered in 208/230v 3 phase and 38YCC 036 through 060 are offered in 460v 3 phase. and Canada), CEC, and ARI.įEATURES Electrical Range - All sizes of the 38YCC are offered in single phase 208– 230v. The 38YCC recovers heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, removes indoor heat and excess humidity during the cooling season. With SEER ratings up to 11.5 and HSPF from 6.8 to 7.6, this heat pump system provides economy of operation through energy conservation when used with components designated by the manufacturer. The 38YCC Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. 38YCC (60 Hz) 10 SEER Heat Pump 38YCC Sizes 018 thru 060